Updating Cisco UCS B Series Infrastructure from firmware 1.4 to 2.0

I’ve been keeping a close eye on when Cisco was going to release their UCS B Series infrastructure 2.0 firmware ever since VMware released vSphere 5 as many customers wanted to know whether they could begin testing how stable the new hypervisor would run in their existing infrastructure.  Needless to say, I was extremely excited when Cisco released the firmware a little more than a week ago.  With that being said, I didn’t have any time to try out the new firmware until mid last week when I was providing UCS training a customer.  Since it was my first time upgrading the firmware and I was explaining the process step-by-step, I took the opportunity to screenshot every step so I could write this blog.  What I noticed during the upgrade was how much more content Cisco included to show how to validate and test the firmware for administrators who are upgrading their production infrastructure.  While the process was very much the same as the 1.x version with some minor differences in ordering, I have to say Cisco did a great job with the extra content they included.

I’m going to by pass the overview, downloading and prerequisites section of the upgrade guide but if you’re performing this upgrade to your production environment, please go through those sections and the release notes so you can be aware of any issues that may pertain to your environment.

Begin by ensuring that you have the correct firmware packages uploaded to your 6100 series fabric interconnects:

image

Updating the Firmware on the Adapters, CIMCs, and IOMs

From within UCS Manager, navigate to the Equipment tab, click on the Equipment node, Firmware Management tab, Installed Firmware sub-tab and finally the Upgrade Firmware button:

image

From within the Update Firmware Window, select ALL for the Filter list and 2.0(1m) for the Set Version list:

image

Proceed with clicking on the Apply button and you’ll notice the Update Status field on the right change from ready to updating:

image

Click on the OK button to close the Update Firmware window and continue monitoring the status from within the Installed Firmware sub-tab window:

image

Continue waiting until the status for all of the components is listed as ready:

image

Activating the Firmware on the Adapters

Now that the firmware is updated, we can proceed with activating the firmware on all of the components and the first set of components to activate are the adapters.  Proceed with clicking on the Activate Firmware button from the Equipment tab, Equipment node, Firmware Management tab, Installed Firmware sub-tab:

image

From within the Activate Firmware Window, select Adapters for the Filter list, 2.0(1m) for the Set Version list, check the Ignore Compatibility Check and Startup Version Only check box:

image

Continue by clicking the Apply button and you’ll see the status of the activation in the Activate Status column:

image

Click on the OK button to close the Activate Firmware window and continue monitoring the status from within the Installed Firmware sub-tab window until you see the status for all of the adapters being listed as pending-next-boot:

image

Activating the Firmware on the CIMCs

Now that the firmware for the adapters have been activated, proceed with activating the firmware for the CIMCs by opening up the Activate Firmware window and select CIMC for the Filter list, 2.0(1m) for the Set Version list, check the Ignore Compatibility Check and Startup Version Only check box:

image

Continue by clicking the Apply button and you’ll see the status of the activation in the Activate Status column:

image

Click on the OK button to close the Activate Firmware window and continue monitoring the status from within the Installed Firmware sub-tab window until you see the status for all of the CIMCs being listed as ready:

image

Activating the Board Controller Firmware on a Server

Unfortunately, I didn’t have any B440 blades in the environment we had in our demo infrastructure so I won’t be able to provide screenshots for it.  Please refer to the manual for more details:

image

Activating the Cisco UCS Manager Software to Release 2.0

Proceed with activating the firmware for the UCS Manager by opening up the Activate Firmware window and select UCS Manager for the Filter list, 2.0(1m) for the Set Version list, check the Ignore Compatibility Check check box:

image

You’ll be prompted with a warning message as soon as you click on the Apply button:

image

Once you’ve answered Yes to the warning message, you’ll be brought back to the Activate Firmware window and the Activate Status will now read scheduled:

image

Click on the OK button to close the Activate Firmware window and continue waiting till you lose your connection to UCS Manager:

image

image

image

Give the 6100 series fabric interconnects to activate the UCS Manager and within a minute or two, you’ll be able to reconnect again:

image

image

Once you’re back into UCS Manager, you should now see that the UCS Manager has 2.0(1m) listed as the Running Version:

image

Activating the Firmware on the IOMs

Proceed with activating the firmware for the IOMs by opening up the Activate Firmware window and select IOM for the Filter list, 2.0(1m) for the Set Version list, check the Ignore Compatibility Check and Startup Version Only check box:

image

Continue by clicking the Apply button and you’ll see the status of the activation in the Activate Status column:

image

Click on the OK button to close the Activate Firmware window and continue monitoring the status from within the Installed Firmware sub-tab window until you see the status for all of the IOMs being listed as Pending Next Boot.

Activating the Fabric Interconnect Firmware for a Cluster Configuration

Activating the firmware on the fabric interconnects requires a specific order so the first step is to identify which fabric interconnect is the primary and subordinate.  This can be easily done by expanding the Fabric Interconnects node under the Equipment tab’s Equipment node:

image

Once you have identified which fabric interconnect is primary and subordinate, we can proceed with activating the subordinate fabric. 

Note that in a VMware ESXi environment, depending on which path the virtual machines are binded to, some of them may experience a slight blip in network disruption when you activate the fabric interconnect.  The disruption will be minimal as they will fail over to the other fabric.  With that being said, if your environment has sensitive applications that are dependent on other servers, disruptions in services can occur so contact the application owners to determine what the best approach for the firmware upgrade because there will be scenarios where it is best to simply shutdown the servers during the upgrade.

Proceed with ensuring that HA is operating correctly for both the primary and subordinate fabric interconnects:

image image

Once you’ve verified that HA is operating correctly, proceed with opening the Activate Firmware window, set the Startup Version for the subordinate fabric interconnect to 5.0(3)N2(2.1m) and check the Ignore Compatibility Check check box:

image

Proceed by clicking the Apply button and you’ll see the Activate Status column update to Activating status:

image

Continue by clicking the OK button to close the Activate Firmware window.  From here, navigate to the subordinate fabric interconnect node, open the General tab then scroll down to the Update Status section:

image

From here, you will be able to monitor the status of the activation:

image

image

As with the earlier versions of 1.x, the subordinate fabric interconnect will light up like a christmas tree changing from red, orange, yellow and back to the various available colours with the status’:

Ready: No

State: Down

Failure Reason: Node Down

Leadership: Inapplicable

Cluster Link State: Full

This is all normal so just for the activation to complete:

image

Keep monitoring the High Availability Details section and you will eventually see the status’ revert back to normal:

Ready: Yes

State: Up

Leadership: Subordinate

Cluster Link State: Full

image

Navigating back to the Installed Firmware tab should now indicate that the firmware version for the Kernel and System is 2.0(1m):

image

With the subordinate fabric interconnect activated with the new 2.0(1m) firmware, continue with activating the primary fabric interconnect by opening the Activate Firmware window, set the Startup Version for the primary fabric interconnect to 5.0(3)N2(2.1m) and check the Ignore Compatibility Check check box:

image

Clicking the apply button will prompt you with a warning message indicating that the fabric interconnect will reboot and thus kicking you off of UCS Manager:

image

Once you have answered Yes to the warning message, you will be returned to the Activate Firmware window where you’ll notice that the Activate Status for the primary firmware is now listed as Activating:

image

Continue by clicking the OK button to close the Activate Firmware window.  From here, navigate to the primary fabric interconnect node, open the General tab then scroll down to the Update Status section:

image

From here, you will be able to monitor the status of the activation:

image

The activation process of the primary fabric interconnect will eventually reboot the 6120/6140 so you’ll eventually get kicked out:

image

You should be able to immediately log back into UCS Manager because the subordinate is supposed to become the primary fabric interconnect:

image

As with the activation of the subordinate fabric interconnect, the primary will light up like a christmas tree changing from red, orange, yellow and back to the various available colours with the status’:

Ready: No

State: Down

Failure Reason: Node Down

Leadership: Inapplicable

Cluster Link State: Full

This is all normal so just for the activation to complete:

image

When you see that the High Availability Details listed as:

Ready: No

State: Up

Failure Reason: Chassis Configuration Incomplete

Leadership: Subordinate

Cluster Link State: Full

… you can expect the clustered fabric interconnect to be fully operational soon:

image

Keep monitoring the High Availability Details section and you will eventually see the status’ revert back to normal:

Ready: Yes

State: Up

Leadership: Subordinate

Cluster Link State: Full

image

Updating a Management and Host Firmware Package

It’s important that once you have the core components of the UCS B series infrastructure upgraded, you will also need to update the reset of the components on the blade servers.  I find that many administrators tend to miss this and what’s nice about the newer firmware versions of 1.4 is that you will actually get warnings about the firmware versions for the blades are old (older firmware never warned you).

Updating a Management Firmware Package

To update the management of the components on the blades, navigate to the Servers tab, Servers node, Policies then right click on the Management Firmware Packages node and select Create Management Firmware Package:

image

Select the packages for the blades you have in the environment, choose the firmware version and provide a name for this package:

image

Once you’ve completed your selection, click the OK button and your firmware package will be created:

image

With the new Management Firmware Package created, you have the option of immediately assigning it to your service profile or service profile templates.  I prefer to complete the creation of the Host Firmware Packages so I don’t need to go back to the same tab to assign the package again.

Updating a Host Firmware Package

To update the other hardware components on the blades, navigate to the Servers tab, Servers node, Policies then right click on the Host Firmware Packages node and select Create Host Firmware Package:

image

Select the packages for the blades you have in the environment, choose the firmware version and provide a name for this package:

image

Make sure you also navigate to the other tabs listed in the window (i.e. Adapter, BIOS, Board Controller, etc):

image

Once you’ve completed your selection, click the OK button and your firmware package will be created.

image

With the new packages created, you can now navigate to the Policies tab of the service profile or service profile templates and assign them:

image

If you were assigning the policies to an actual service profile, you’ll be warned that the operation will cause the blade to reboot:

image

If you answer yes, your blade will reboot and then go through the updating process:

image

image

It’s important that you navigate to the Installed Firmware tab to ensure that the components have updated:

image

… and that’s it.  The process is very much the same as 1.x  version and while I understand that the manual is extremely straight forward with what needs to be done, I hope this post serves to provide some visual aids through the use of screenshots to demonstrate what the process looks like.

2 comments:

Anonymous said...

hi Terrence,

may i ask you something about UCS?
maybe this is out of topic from this firmware discussion.

1. i have problem with installing w2k3 x64 directly to the ucs servers, the ISO installation running well. but the LSI SAS driver cannot be load into the floppy drive, i already mount some LSI driver 1064E to floppy drive. but the windows installation couldn't find it.

2. can i install the windows 2000 natively on UCS B-series?? can you show me how?

thank you Terrence, hopely you can reply me as soon as posible.

Regards

Vincent Dumouchel said...

Very helpful tanks you!!!